FS#16650 - [conky] 1.7.2-3 breaks hwmon sensors detection.
Attached to Project:
Arch Linux
Opened by Wes Brewer (zer0) - Wednesday, 14 October 2009, 16:32 GMT
Last edited by Giovanni Scafora (giovanni) - Friday, 16 October 2009, 20:32 GMT
Opened by Wes Brewer (zer0) - Wednesday, 14 October 2009, 16:32 GMT
Last edited by Giovanni Scafora (giovanni) - Friday, 16 October 2009, 20:32 GMT
|
Details
Description:
Conky-1.7.2-3 doesn't start anymore when hwmon variable is used in .conkyrc config. It's error output complains about hwmon sensors locations. Error: "Conky: can't open '/sys/class/hwmon/hwmon0/temp3_input': No such file or directory please check your device or remove this var from Conky..." Seaching through /sys/class/hwmon/hwmon0/ reveals that temp3_input (and all other sensors) are not there. They are however deeper in the directory at /sys/class/hwmon/hwmon0/device/. Downgrading to previous version conky-1.7.2-1 and conky runs as expected without error. Affected versions: conky-1.7.2-2 conky-1.7.2-3 Sensors used: w83627ehf |
This task depends upon
Closed by Giovanni Scafora (giovanni)
Friday, 16 October 2009, 20:32 GMT
Reason for closing: Won't fix
Friday, 16 October 2009, 20:32 GMT
Reason for closing: Won't fix
http://bbs.archlinux.org/viewtopic.php?id=82231
Theres updated patch here, which should work for both cases AFAIK:
http://bazaar.launchpad.net/~norsetto/%2Bjunk/conky/annotate/head%3A/patches/fix_hwmon_for_2.6.31.patch