Arch Linux

Please read this before reporting a bug:
https://wiki.archlinux.org/title/Bug_reporting_guidelines

Do NOT report bugs when a package is just outdated, or it is in the AUR. Use the 'flag out of date' link on the package page, or the Mailing List.

REPEAT: Do NOT report bugs for outdated packages!
Tasklist

FS#28438 - [fglrx/mplayer] segfault

Attached to Project: Arch Linux
Opened by Alexandre Bique (babali) - Wednesday, 15 February 2012, 07:33 GMT
Last edited by Ionut Biru (wonder) - Monday, 05 March 2012, 09:42 GMT
Task Type Bug Report
Category Packages: Extra
Status Closed
Assigned To No-one
Architecture All
Severity Low
Priority Normal
Reported Version
Due in Version Undecided
Due Date Undecided
Percent Complete 100%
Votes 1
Private No

Details

Hi,

When I start mplayer, Xorg segfaults.

Name : catalyst
Version : 11.12-1

Name : mplayer
Version : 34426-3
This task depends upon

Closed by  Ionut Biru (wonder)
Monday, 05 March 2012, 09:42 GMT
Reason for closing:  Won't fix
Comment by Alexandre Bique (babali) - Wednesday, 15 February 2012, 07:34 GMT
lspci
00:00.0 Host bridge: Intel Corporation 5520 I/O Hub to ESI Port (rev 22)
00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 22)
00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 22)
00:07.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 7 (rev 22)
00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 22)
00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 22)
00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 22)
00:1a.0 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4
00:1a.1 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5
00:1a.2 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6
00:1a.7 USB controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2
00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller
00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1
00:1c.5 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 6
00:1d.0 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1
00:1d.1 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2
00:1d.2 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3
00:1d.7 USB controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1
00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90)
00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller
00:1f.2 RAID bus controller: Intel Corporation 82801 SATA RAID Controller
00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller
01:00.0 PCI bridge: Pericom Semiconductor PCI Express to PCI-XPI7C9X130 PCI-X Bridge (rev 04)
03:00.0 VGA compatible controller: ATI Technologies Inc RV620 [FirePro 2260]
06:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5761 Gigabit Ethernet PCIe (rev 10)
07:04.0 Ethernet controller: D-Link System Inc RTL8139 Ethernet (rev 10)
20:07.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 7 (rev 22)
20:09.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 9 (rev 22)
20:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 22)
20:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 22)
20:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 22)
23:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1068E PCI-Express Fusion-MPT SAS (rev 08)
3e:00.0 Host bridge: Intel Corporation Xeon 5600 Series QuickPath Architecture Generic Non-core Registers (rev 02)
3e:00.1 Host bridge: Intel Corporation Xeon 5600 Series QuickPath Architecture System Address Decoder (rev 02)
3e:02.0 Host bridge: Intel Corporation Xeon 5600 Series QPI Link 0 (rev 02)
3e:02.1 Host bridge: Intel Corporation Xeon 5600 Series QPI Physical 0 (rev 02)
3e:02.2 Host bridge: Intel Corporation Xeon 5600 Series Mirror Port Link 0 (rev 02)
3e:02.3 Host bridge: Intel Corporation Xeon 5600 Series Mirror Port Link 1 (rev 02)
3e:02.4 Host bridge: Intel Corporation Xeon 5600 Series QPI Link 1 (rev 02)
3e:02.5 Host bridge: Intel Corporation Xeon 5600 Series QPI Physical 1 (rev 02)
3e:03.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Registers (rev 02)
3e:03.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Target Address Decoder (rev 02)
3e:03.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller RAS Registers (rev 02)
3e:03.4 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Test Registers (rev 02)
3e:04.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Control (rev 02)
3e:04.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Address (rev 02)
3e:04.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Rank (rev 02)
3e:04.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Thermal Control (rev 02)
3e:05.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Control (rev 02)
3e:05.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Address (rev 02)
3e:05.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Rank (rev 02)
3e:05.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Thermal Control (rev 02)
3e:06.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Control (rev 02)
3e:06.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Address (rev 02)
3e:06.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Rank (rev 02)
3e:06.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Thermal Control (rev 02)
3f:00.0 Host bridge: Intel Corporation Xeon 5600 Series QuickPath Architecture Generic Non-core Registers (rev 02)
3f:00.1 Host bridge: Intel Corporation Xeon 5600 Series QuickPath Architecture System Address Decoder (rev 02)
3f:02.0 Host bridge: Intel Corporation Xeon 5600 Series QPI Link 0 (rev 02)
3f:02.1 Host bridge: Intel Corporation Xeon 5600 Series QPI Physical 0 (rev 02)
3f:02.2 Host bridge: Intel Corporation Xeon 5600 Series Mirror Port Link 0 (rev 02)
3f:02.3 Host bridge: Intel Corporation Xeon 5600 Series Mirror Port Link 1 (rev 02)
3f:02.4 Host bridge: Intel Corporation Xeon 5600 Series QPI Link 1 (rev 02)
3f:02.5 Host bridge: Intel Corporation Xeon 5600 Series QPI Physical 1 (rev 02)
3f:03.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Registers (rev 02)
3f:03.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Target Address Decoder (rev 02)
3f:03.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller RAS Registers (rev 02)
3f:03.4 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Test Registers (rev 02)
3f:04.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Control (rev 02)
3f:04.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Address (rev 02)
3f:04.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Rank (rev 02)
3f:04.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 0 Thermal Control (rev 02)
3f:05.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Control (rev 02)
3f:05.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Address (rev 02)
3f:05.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Rank (rev 02)
3f:05.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 1 Thermal Control (rev 02)
3f:06.0 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Control (rev 02)
3f:06.1 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Address (rev 02)
3f:06.2 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Rank (rev 02)
3f:06.3 Host bridge: Intel Corporation Xeon 5600 Series Integrated Memory Controller Channel 2 Thermal Control (rev 02)
Comment by Ionut Biru (wonder) - Wednesday, 15 February 2012, 08:37 GMT
is an old catalyst issue and xorg-server 1.11. you should forward this to AMD
Comment by Alexandre Bique (babali) - Wednesday, 15 February 2012, 08:47 GMT
Yes I am looking at ati.amd.com and I see that there is a most recent driver for me: http://www2.ati.com/drivers/firepro/FirePro_8.911.3.1_Linux_X32X64_132092.zip

But I don't know if there is any pkgbuild which correspond to it ?
Comment by Ionut Biru (wonder) - Wednesday, 15 February 2012, 08:50 GMT
search in AUR for catalyst. We do not support this driver and therefor i'll close this bug.

Loading...