FS#25412 - [lxpanel] version 0.5.8 - battery monitor always shows 100%

Attached to Project: Community Packages
Opened by myrlin (myrlin) - Friday, 05 August 2011, 18:06 GMT
Last edited by Bartłomiej Piotrowski (Barthalion) - Saturday, 24 December 2011, 11:33 GMT
Task Type Bug Report
Category Packages
Status Closed
Assigned To Bartłomiej Piotrowski (Barthalion)
Architecture All
Severity Medium
Priority Normal
Reported Version
Due in Version Undecided
Due Date Undecided
Percent Complete 100%
Votes 5
Private No

Details

Description:
Battery monitor always shows 100% in version 0.5.8 of lxpanel. Colour changes correctly when switched from battery to power. "acpi -b" gives correct reading.
Downgrading to version 0.5.6 fixes the problem.

Additional info:
Hardware Used: EeePC 901

This seems to be a re-introduction of a bug reported (and fixed) in version 0.5.5 (ref: http://lists.alioth.debian.org/pipermail/pkg-lxde-maintainers/2010-May/000074.html)


Steps to reproduce:

Always present.
This task depends upon

Closed by  Bartłomiej Piotrowski (Barthalion)
Saturday, 24 December 2011, 11:33 GMT
Reason for closing:  Fixed
Additional comments about closing:  Fixed in 0.5.8-2.
Comment by Jouke Witteveen (jouke) - Sunday, 25 September 2011, 11:34 GMT
The attached patch fixes a few things:
- battery_new uses battery_reset, so declare that first
- do not divide by zero for old/defective batteries that report zero voltage
- calculate the percentage in general

The last item on that list is a regression. Since the quality of computers at my disposal at this moment is very minimal, I am not sending this upstream. I could not figure out the procedure, apart from some pointless patch-stacking in sourceforge where the developers do not seem to harvest very often. Feel free to forward this patch.
Comment by Angel Velasquez (angvp) - Wednesday, 21 December 2011, 21:25 GMT
I'm not the maintainer of lxpanel anymore