Please read this before reporting a bug:
https://wiki.archlinux.org/title/Bug_reporting_guidelines
Do NOT report bugs when a package is just outdated, or it is in the AUR. Use the 'flag out of date' link on the package page, or the Mailing List.
REPEAT: Do NOT report bugs for outdated packages!
https://wiki.archlinux.org/title/Bug_reporting_guidelines
Do NOT report bugs when a package is just outdated, or it is in the AUR. Use the 'flag out of date' link on the package page, or the Mailing List.
REPEAT: Do NOT report bugs for outdated packages!
FS#22039 - [upower] doesn't detect battery
Attached to Project:
Arch Linux
Opened by Stephan Zeisberg (stze) - Friday, 10 December 2010, 14:55 GMT
Last edited by Ionut Biru (wonder) - Saturday, 11 December 2010, 21:20 GMT
Opened by Stephan Zeisberg (stze) - Friday, 10 December 2010, 14:55 GMT
Last edited by Ionut Biru (wonder) - Saturday, 11 December 2010, 21:20 GMT
|
DetailsDescription: upower does not detect battery
Additional info: $ upower -d (upower:2740): libupower-glib-WARNING **: Couldn't enumerate devices: Launch helper exited with unknown return code 127 (upower:2740): UPower-WARNING **: failed to enumerate: Launch helper exited with unknown return code 127 but $ cat /proc/acpi/battery/BAT0/state present: yes capacity state: ok charging state: charged present rate: 0 mA remaining capacity: 4388 mAh present voltage: 12534 mV Steps to reproduce: upower -d gnome-power-manager doesn't show battery tab. package: upower 0.9.7-2 x86_64 |
This task depends upon
https://bugs.freedesktop.org/enter_bug.cgi?product=upower